CLTO=OFF, BITO=OFF, CLHR=STANDARD
Control Register
| EN | I2C Enable |
| SLAVE | Addressable as Slave |
| AUTOACK | Automatic Acknowledge |
| AUTOSE | Automatic STOP when Empty |
| AUTOSN | Automatic STOP on NACK |
| ARBDIS | Arbitration Disable |
| GCAMEN | General Call Address Match Enable |
| CLHR | Clock Low High Ratio 0 (STANDARD): The ratio between low period and high period counters (Nlow:Nhigh) is 4:4 1 (ASYMMETRIC): The ratio between low period and high period counters (Nlow:Nhigh) is 6:3 2 (FAST): The ratio between low period and high period counters (Nlow:Nhigh) is 11:6 |
| BITO | Bus Idle Timeout 0 (OFF): Timeout disabled 1 (40PCC): Timeout after 40 prescaled clock cycles. In standard mode at 100 kHz, this results in a 50us timeout. 2 (80PCC): Timeout after 80 prescaled clock cycles. In standard mode at 100 kHz, this results in a 100us timeout. 3 (160PCC): Timeout after 160 prescaled clock cycles. In standard mode at 100 kHz, this results in a 200us timeout. |
| GIBITO | Go Idle on Bus Idle Timeout |
| CLTO | Clock Low Timeout 0 (OFF): Timeout disabled 1 (40PCC): Timeout after 40 prescaled clock cycles. In standard mode at 100 kHz, this results in a 50us timeout. 2 (80PCC): Timeout after 80 prescaled clock cycles. In standard mode at 100 kHz, this results in a 100us timeout. 3 (160PCC): Timeout after 160 prescaled clock cycles. In standard mode at 100 kHz, this results in a 200us timeout. 4 (320PPC): Timeout after 320 prescaled clock cycles. In standard mode at 100 kHz, this results in a 400us timeout. 5 (1024PPC): Timeout after 1024 prescaled clock cycles. In standard mode at 100 kHz, this results in a 1280us timeout. |